INSTRUCTIONS FOR INSTALLING REVERSE OSMOSIS AUTO SHUT-OFF PARTS INCLUDED: FLOAT VALVE ASSEMBLY, AUTO SHUT-OFF MODULE, 8 FT. 1/4" PRESSURE HOSING 1. INSTALL HOSING FROM THE OUTPUT SIDE OF THE CARBON FILTER HOUSING TO "IN" CONNECTION (#1 ON DIAGRAM) ON THE SHUT-OFF MODULE. 2. INSTALL HOSING FROM "OUT" (#2 ON DIAGRAM) CONNECTION ON SHUT- OFF MODULE TO THE INPUT SIDE OF THE REVERSE OSMOSIS MEMBRANE. (SINGLE FITTING AT END OF THE MEMBRANE) 3. (FOR MODELS URP25, URP50, URP100) INSTALL THE BLUE HOSING (PURE WATER LINE), THAT COMES FROM THE END OF THE REVERSE OSMOSIS MEMBRANE WERE THERE ARE 2 FITTINGS. TO THE CONNECTION BELOW "OUT" (#3 ON DIAGRAM) CONNECTION ON SHUT-OFF MODULE. (FOR MODELS POL25, POL50, POL100) INSTALL THE BLUE HOSING (PURE WATER LINE), THAT COMES FROM THE OUTPUT OF THE DEIONZING CHAMBER TO THE CONNECTION BELOW THE "OUT" (#3 ON DIAGRAM) CONNECTION ON THE SHUT-OFF MODULE. 4. INSTALL THE FLOAT VALVE INTO AN OPEN-AIR STORAGE TANK, THEN ATTACH THE HOSING BETWEEN THE FLOAT VALVE AND TO THE CONNECTION BELOW THE "IN" (#4 ON DIAGRAM) CONNECTION ON SHUT-OFF MODULE. 5. INSTALL THE CHECK VALVE (1/8" COMPRESSION ELBOW) INTO THE "PURE WATER" OUTPUT FROM THE R.O. MEMBRANE HOUSING (END OF REVERSE OSMOSIS MEMBRANE WERE THERE ARE 2 FITTINGS. (YOU NEED TO REMOVE THE EXISTING ELBOW FITTING FIRST). ------------------------ 2. | OUT IN | 1. | | | | 3. | | 4. | | ------------------------ WHITE SHUT-OFF MODULE